In-syringe magnetic stirring assisted dispersive liquid-liquid microextraction with solvent washing for fully automated determination of cationic surfactants

Show simple item record

dc.contributor.author Horstkotte, B.
dc.contributor.author Suárez, R.
dc.contributor.author Solich, P.
dc.contributor.author Cerdà, V.
dc.date.accessioned 2020-04-24T06:43:34Z
dc.identifier.uri http://hdl.handle.net/11201/152114
dc.description.abstract [eng] An automated simple analyzer system for the extraction of cationic surfactants as an ion-pair with disulfine blue dye is described based on the technique in-syringe magnetic stirring-assisted dispersive liquid-liquid micro-extraction. The use of chloroform as an extraction solvent denser than water required to operate the syringe pump upside-down. The remaining air cushion inside the syringe allowed emptying the syringe completely and reducing the dead volume significantly compared to prior works. Since the stirring bar placed inside the syringe to obtain a closed yet size-adaptable mixing chamber remains at the same position, the former magnetic stirring bar driver was simplified. The new system configuration further enabled automated in-syringe washing of the organic phase with water and barium acetate solution to minimize interferences. High signal repeatability with < 5 % RSD was achieved both for extraction as well as for double organic phase washing. Only 220 µL of extraction solvent and 4 mL of sample were required for simple extraction achieving a detection limit below 30 nmol L-1 and a linear response up to 1 µmol L-1 of cetyltriamethylammonium bromide. The time of analysis was 240 s for simple extraction. Considerable reduction of interferences was achieved by extract washing requiring up to 545 s. Analyte recovery in real water samples was 95.6 ± 7.0 % applying extract washing
dc.format application/pdf
dc.relation.isformatof Versió postprint del document publicat a: https://doi.org/10.1039/c4ay01695e
dc.relation.ispartof Analytical Methods, 2014, vol. 6, p. 9601-9609
dc.rights (c) Horstkotte, B. et al., 2014
dc.subject.classification 54 - Química
dc.subject.other 54 - Chemistry. Crystallography. Mineralogy
dc.title In-syringe magnetic stirring assisted dispersive liquid-liquid microextraction with solvent washing for fully automated determination of cationic surfactants
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/acceptedVersion
dc.date.updated 2020-04-24T06:43:34Z
dc.date.embargoEndDate info:eu-repo/date/embargoEnd/2026-12-31
dc.embargo 2026-12-31
dc.subject.keywords Flow Injection Analysis
dc.subject.keywords Multisyringe flow injection analysis
dc.rights.accessRights info:eu-repo/semantics/embargoedAccess
dc.identifier.doi https://doi.org/10.1039/c4ay01695e


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics