Reliability and minimal detectable change of three functional tests: forward-lunge, step-up-over and sit-to-stand

Show simple item record

dc.contributor.author Luque-Siles, Carmen
dc.contributor.author Gallego-Izquierdo, Tomás
dc.contributor.author Jímenez-Rejano, Jesus Juan
dc.contributor.author de-la-Orden, Susana
dc.contributor.author Plaza-Manzano, Gustavo
dc.contributor.author López-Illescas-Ruiz, Africa
dc.contributor.author Ferragut-Garcías, Alejandro
dc.contributor.author Romero-Franco, Natalia
dc.contributor.author Martín-Casas, Patricia
dc.contributor.author Pecos-Martín, Daniel
dc.date.accessioned 2020-05-21T08:48:32Z
dc.date.available 2020-05-21T08:48:32Z
dc.identifier.uri http://hdl.handle.net/11201/152492
dc.description.abstract [eng] [Purpose] To examine the intrasession and intersession reliability and the absolute reliability of three functional dynamic tests forward-lunge, step-up-over and sit-to-stand tests using computerized dynamic posturography. [Subjects and Methods] An intra-test and test-retest, repeated measure study was designed. Forty-five healthy subjects twice carried out the forward-lunge test, step-up-over test, and sit-to-stand test on two days, one week apart. The intrasession and intersession reliabilities as judged by the intraclass correlation coefficient (ICC) and the minimal detectable change of the three functional tests were calculated. [Results] Excellent to very good intrasession reliability of the forward-lunge test (ICC range of 0.9-0.8) was found. Very good to good intrasession reliability of the step-up-over test (ICC range of 0.9-0.5) was found and very good intrasession reliability of the sit-to-stand test (ICC range of 0.8-0.7) was found. The minimal detectable change at the 95% confidence level of most of the measures was lower than 30%. [Conclusion] The forward-lunge, step-up-over and sit-to-stand tests are reliable measurement tools.
dc.format application/pdf
dc.relation.isformatof https://doi.org/10.1589/jpts.28.3384
dc.relation.ispartof Journal Of Physical Therapy Science, 2016, vol. 28, num. 12, p. 3384-3389
dc.rights , 2016
dc.subject.classification 614 - Higiene i salut pública. Contaminació. Prevenció d'accidents. Infermeria
dc.subject.other 614 - Public health and hygiene. Accident prevention
dc.title Reliability and minimal detectable change of three functional tests: forward-lunge, step-up-over and sit-to-stand
dc.type info:eu-repo/semantics/article
dc.date.updated 2020-05-21T08:48:32Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1589/jpts.28.3384


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics