Fully automatic in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction hyphenated to high temperature torch integrated sample introduction system-inductively coupled plasma spectrometer with direct injection of the organic phase

Show simple item record

dc.contributor.author Sánchez, Raquel
dc.contributor.author Horstkotte, Burkhard
dc.contributor.author Fikarová, Kateřina
dc.contributor.author Sklenářová, Hana
dc.contributor.author Maestre, Salvador
dc.contributor.author Miró, Manuel
dc.contributor.author Todolí, Jose-Luis
dc.date.accessioned 2021-10-25T07:09:18Z
dc.date.available 2021-10-25T07:09:18Z
dc.identifier.uri http://hdl.handle.net/11201/155943
dc.description.abstract [eng] A proof of concept study involving the online coupling of automatic dispersive liquid-liquid microextraction (DLLME) to inductively coupled plasma optical emission spectrometry (ICP OES) with direct introduction and analysis of the organic extract is herein reported for the first time. The flow-based analyzer features a lab-in-syringe (LIS) setup with an integrated stirring system, a Meinhard nebulizer in combination with a heated single-pass spray chamber, and a rotary injection valve, used as an online interface between the microextraction system and the detection instrument. Air-segmented flow was used for delivery of a fraction of the nonwater miscible extraction phase, 12 μL of xylene, to the nebulizer. All sample preparative steps including magnetic stirring assisted DLLME were carried out inside the syringe void volume as a size-adaptable yet sealed mixing and extraction chamber. Determination of trace level concentrations of cadmium, copper, lead, and silver as model analytes has been demonstrated by microextraction as diethyldithiophosphate (DDTP) complexes. The automatic LIS-DLLME method features quantitative metal extraction, even in troublesome sample matrixes, such as seawater, salt, and fruit juices, with relative recoveries within the range of 94-103%, 93-100%, and 92-99%, respectively. Furthermore, no statistically significant differences at the 0.05 significance level were found between concentration values experimentally obtained and the certified values of two serum standard reference materials.
dc.format application/pdf
dc.relation.isformatof Versió postprint del document publicat a: https://doi.org/10.1021/acs.analchem.7b00400
dc.relation.ispartof Analytical Chemistry, 2017, vol. 89, num. 6, p. 3787-3794
dc.subject.classification 54 - Química
dc.subject.other 54 - Chemistry. Crystallography. Mineralogy
dc.title Fully automatic in-syringe magnetic stirring-assisted dispersive liquid-liquid microextraction hyphenated to high temperature torch integrated sample introduction system-inductively coupled plasma spectrometer with direct injection of the organic phase
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/acceptedVersion
dc.date.updated 2021-10-25T07:09:18Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1021/acs.analchem.7b00400


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics