Automated sequential injection-capillary electrophoresis for dried blood spot analysis: A proof-of-concept study

Show simple item record

dc.contributor.author Dvorak, Milos
dc.contributor.author Miró, Manuel
dc.contributor.author Kuban, Pavel
dc.date.accessioned 2023-07-06T12:14:44Z
dc.date.available 2023-07-06T12:14:44Z
dc.identifier.uri http://hdl.handle.net/11201/161132
dc.description.abstract [eng] A hyphenated analytical platform that enables fully automated analyses of dried blood spots (DBSs) is proposed by the at-line coupling of sequential injection (SI) to capillary electrophoresis (CE). The SI system, exploited herein for the first time for unattended DBS handling, serves as the "front end" mesofluidic platform for facilitating exhaustive elution of the entire DBS by flow programming. The DBS eluates are thus free from hematocrit and nonhomogeneity biases. The SI pump transfers the resulting DBS eluates into CE sample vials through an internal port of the CE instrument and homogenizes the eluates, whereupon the eluted blood compounds are automatically injected, separated, and quantified by the CE instrument. The SI and CE are commercially available off-the-shelf instruments and are interconnected through standard nuts, ferrules, and tubing without additional instrumental adjustments. They are controlled by dedicated software and are synchronized for a fully autonomous operation. The direct determination of endogenous (potassium and sodium) and exogenous (lithium as a model drug) inorganic cations in DBS samples has been used for the proof-of-concept demonstration. The hyphenated SI-CE platform provides excellent precision of the analytical method with relative standard deviation (RSD) values of peak areas below 1.5 and 3.5% for intraday and interday analyses, respectively, of the endogenous concentrations of the two inorganic cations. For the determination of lithium, calibration is linear in a typical clinical range of the drug (R2 better than 0.9993 for 2-20 mg/L), RSD values of peak areas are below 4.5% (in the entire calibration range), the limit of detection (0.4 mg/L) and the limit of quantification (1.3 mg/L) are well below the drug's minimum therapeutic concentration (4 mg/L), and total analysis time is shorter than 5 min. The SI-CE platform reflects the actual trends in the automation of analytical methods, offers rapid and highly flexible DBS elution/analysis processes, and might thus provide a general solution to modern clinical analysis as it can be applied to a broad range of analytes and dried biological materials.
dc.format application/pdf
dc.relation.isformatof Versió postprint del document publicat a: https://doi.org/10.1021/acs.analchem.1c05130
dc.relation.ispartof Analytical Chemistry, 2022, vol. 94, num. 13, p. 5301-5309
dc.subject.classification 54 - Química
dc.subject.other 54 - Chemistry. Crystallography. Mineralogy
dc.title Automated sequential injection-capillary electrophoresis for dried blood spot analysis: A proof-of-concept study
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/acceptedVersion
dc.date.updated 2023-07-06T12:14:44Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1021/acs.analchem.1c05130


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics