Procedure to obtain the optimal distribution cooling capacity of an air-condensed chiller plant for a hotel facility conceptual design

Show simple item record

dc.contributor.author Díaz Torres, Yamile
dc.contributor.author Reyes Calvo, Roy
dc.contributor.author Hernández Herrera, Hernán
dc.contributor.author Álvarez Guerra, Mario A.
dc.contributor.author Gómez Sarduy, Julio
dc.contributor.author Silva Ortega, Jorge Iván
dc.date.accessioned 2024-04-25T08:19:09Z
dc.date.available 2024-04-25T08:19:09Z
dc.identifier.uri http://hdl.handle.net/11201/165476
dc.description.abstract [eng] The article presents a novel methodology for designing chiller plants for a hotel facility to determine the optimal distribution of the chillers cooling capacity that compose the plant. The methodology proposes three phases. In the first, the statistical analysis allowed to determine the cooling demand required in the facility, where the constructed thermal demand profiles reflect future operating conditions, and to obtain the individual cooling capacities of the chillers. In the second phase, the black box models were built to simulate the chillers energy performance and, using a mathematical algorithm allows to obtain a combination of chiller plants. The third phase constitutes the energy evaluation through the solution of a mathematical optimization problem and using a genetic algorithm. This was carried out under the sequence approach and the optimal load of each machine against the working conditions. This analysis allows calculating the performance, the life cycle cost, and the indirect environmental impact. The paper proposes a case study to demonstrate the feasibility of applying the methodology to the initial design stage, achieving a saving of 14,4%. Finally, using statistical analysis, the method allows comparing the relationship between each chiller plant considering the design and operating parameters
dc.format application/pdf
dc.relation.isformatof https://doi.org/10.1016/j.egyr.2021.07.090
dc.relation.ispartof Energy Reports, 2021, vol. 7, num. 5 (supplement), p. 622-637
dc.rights , 2021
dc.subject.classification 624 - Enginyeria civil i de la construcció en general
dc.subject.other 624 - Civil and structural engineering in general Substructures. Earthworks. Foundations. Tunnelling. Bridge construction. Superstructures
dc.title Procedure to obtain the optimal distribution cooling capacity of an air-condensed chiller plant for a hotel facility conceptual design
dc.type info:eu-repo/semantics/article
dc.date.updated 2024-04-25T08:19:09Z
dc.subject.keywords Genetic algorithm
dc.subject.keywords Hotel facilities
dc.subject.keywords chiller plant
dc.subject.keywords Cooling capacity
dc.subject.keywords optimal chiller loading
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1016/j.egyr.2021.07.090