On-site stir-blade microextraction combined with dual-polarity direct infusion mass spectrometry for analysis of atrazine, daidzein, and genistein in environmental water samples

Show simple item record

dc.contributor.author Calero-Cañuelo, Carlos
dc.contributor.author Casado-Carmona, Francisco Antonio
dc.contributor.author Lucena, Rafael
dc.contributor.author Cárdenas, Soledad
dc.date.accessioned 2025-10-23T08:24:09Z
dc.date.available 2025-10-23T08:24:09Z
dc.identifier.citation Calero-Cañuelo, C., Casado-Carmona, F. A., Lucena, R. i Cárdenas, S. (2025). On-site stir-blade microextraction combined with dual-polarity direct infusion mass spectrometry for analysis of atrazine, daidzein, and genistein in environmental water samples. Green Analytical Chemistry, 15(100304). https://doi.org/10.1016/j.greeac.2025.100304 ca
dc.identifier.uri http://hdl.handle.net/11201/171698
dc.description.abstract [eng] Integration has emerged as the latter driving force in the evolution of sample preparation, greening analytical measurements through the minimization of steps and their inherent required resources. This article presents the integration of sampling and extraction under a stir-blade microextraction format. For this purpose, commercial blades coated with hydrophilic-lipophilic balance (HLB) microbeads are stirred into the sample thanks to a 5 V demanding miniature motor placed in the cap of the sampling bottle. The broad extraction scope of the HLB sorptive phase, combined with the final analysis of the eluates by dual-polarity direct infusion mass spectrometry, enables the determination of atrazine, daidzein, and genistein (belonging to two different families of organic contaminants) in a single extraction. The portability of the device, as well as the stability of the analytes once extracted in the blade, open the door to the on-site extraction, simplifying the overall analytical procedure. This combination enabled the determination of both classes of pollutants with a limit of quantification of 0.75 µg·L-1 and an inter-day precision (expressed as relative standard deviation) better than 15.4 %. Finally, the potential for the application of this methodology in environmental analysis (river water samples) was demonstrated with relative recoveries in the range of 89 to 127 %. Moreover, the proposed method was evaluated in terms of analytical performance (RAPI), applicability (BAGI), and sustainability (AGREEprep) using the appropriate metric tools, exhibiting results that demonstrate its potential. en
dc.format application/pdf en
dc.publisher Elsevier
dc.relation info:eu-repo/grantAgreement/AEI/10.13039/501100011033//PID2023-146313OB-I00/[ES]
dc.relation info:eu-repo/grantAgreement/AEI//FPU20/04765/[ES]
dc.relation.ispartof Green Analytical Chemistry, 2025, vol. 15, num. 100304 en
dc.rights Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject.classification 54 - Química ca
dc.subject.other 54 - Chemistry. Crystallography. Mineralogy en
dc.title On-site stir-blade microextraction combined with dual-polarity direct infusion mass spectrometry for analysis of atrazine, daidzein, and genistein in environmental water samples en
dc.type info:eu-repo/semantics/article
dc.type info:eu-repo/semantics/publishedVersion
dc.type Article
dc.date.updated 2025-10-23T08:24:10Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.1016/j.greeac.2025.100304


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 International Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 International

Search Repository


Advanced Search

Browse

My Account

Statistics