Balance measurement using Microsoft Kinect v2: Towards remote evaluation of patient with the functional Reach Test

Show simple item record

dc.contributor.author Ayed, Ines
dc.contributor.author Jaume-i-Capó, Antoni
dc.contributor.author Martínez-Bueso, Pau
dc.contributor.author Mir, Arnau
dc.contributor.author Moyà Alcover, Gabriel
dc.date.accessioned 2021-07-12T06:27:39Z
dc.date.available 2021-07-12T06:27:39Z
dc.identifier.uri http://hdl.handle.net/11201/155653
dc.description.abstract [eng] To prevent falls, it is important to measure periodically the balance ability of an individual using reliable clinical tests. As Red Green Blue Depth (RGBD) devices have been increasingly used for balance rehabilitation at home, they may also be used to assess objectively the balance ability and determine the effectiveness of a therapy. For this, we developed a system based on the Microsoft Kinect v2 for measuring the Functional Reach Test (FRT); one of the most used balance clinical tools to predict falls. Two experiments were conducted to compare the FRT measures computed by our system using the Microsoft Kinect v2 with those obtained by the standard method, i.e., manually. In terms of validity, we found a very strong correlation between the two methods (r = 0.97 and r = 0.99 (p < 0.05), for experiments 1 and 2, respectively). However, we needed to correct the measurements using a linear model to fit the data obtained by the Kinect system. Consequently, a linear regression model has been applied and examining the regression assumptions showed that the model works well for the data. Applying the paired t-test to the data after correction indicated that there is no statistically significant difference between the measurements obtained by both methods. As for the reliability of the test, we obtained good to excellent within repeatability of the FRT measurements tracked by Kinect (ICC = 0.86 and ICC = 0.99, for experiments 1 and 2, respectively). These results suggested that the Microsoft Kinect v2 device is reliable and adequate to calculate the standard FRT
dc.format application/pdf
dc.relation.isformatof https://doi.org/10.3390/app11136073
dc.relation.ispartof Applied Sciences-Basel, 2021, vol. 11, num. 13, p. 6073-1-6073-21
dc.rights , 2021
dc.subject.classification 51 - Matemàtiques
dc.subject.classification 004 - Informàtica
dc.subject.other 51 - Mathematics
dc.subject.other 004 - Computer Science and Technology. Computing. Data processing
dc.title Balance measurement using Microsoft Kinect v2: Towards remote evaluation of patient with the functional Reach Test
dc.type info:eu-repo/semantics/article
dc.date.updated 2021-07-12T06:27:40Z
dc.rights.accessRights info:eu-repo/semantics/openAccess
dc.identifier.doi https://doi.org/10.3390/app11136073


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search Repository


Advanced Search

Browse

My Account

Statistics